Biosafety Cabinet Class II Type A2

Biosafety Cabinet Class II Type A2

Precision | Performance | Partnership. We design, manufacture and supply Class 2 Biosafety Cabinets Type A2 for laboratory and research applications.

These Type A2 Class II Biological Safety Cabinets have an open front design provided with negative pressure generation module. Type A2 cabinets are typically used for biosafety levels 1 through 3 and are suitable for work with chemicals, as long as vapors are not hazardous and will not interfere with the work when recirculated. Cabinets protect from contamination of the works, experiment or process from outside contaminants.

The ergonomic internal design, the airflow aerodynamics, the built-in safety devices and the advanced level of construction, ensure the highest performances at the most stringent safety levels, as specified by International standards.

Salient Features

Engineered with unidirectional airflow, HEPA filtration, personnel, product, and environment protection.

  • A front access opening with carefully maintained inward air flow.
  • Internal blower maintains minimum average fpm at face opening.
  • Approximately 70% of air is recirculated through HEPA filter back to work area, 30% exhausted through HEPA filter.
  • Room air enters through pre filter and HEPA filter as vertical unidirectional airflow.
  • Negative pressure maintains inward air flow in chamber.
  • Max safe door opening height: 8" during operation, 15" while cleaning / material loading & unloading.
  • Work table at a height of 760 mm for comfortable sitting position.
  • Aerodynamic airflow grills prevent blockage.
  • High efficiency pre filter increases HEPA filter life.
  • Manufactured as per NSF/ANSI 49 USA standard, EN 12469 European guidelines and ISO 14644-1.
  • Noise level is less than 62 dB ±3dB.



Specifications


Parameters SAII-BSC-A2-2 SAII-BSC-A2-3 SAII-BSC-A2-4 SAII-BSC-A2-5 SAII-BSC-A2-6
Main Filter HEPA Filter (99.99% efficient at 0.3 micron particulate for air quality ISO 5 Class 100)
Pre-filter High-efficiency washable pre filter having efficiency 90% down to 5 micron
Illumination LED light of 5/10/15/20 W (greater than 1200 LUX as per standard guidelines)
Front Door UV Germicidal Tube of 254 nm wavelength
Utility Sliding type safety door made of plexi glass fitted in aluminum frame with counter balanced weight mechanism
Pressure Gauge Gas/Air cock and Multipoint 15/5 Amp. electric socket
Flow Velocity Inclined Manometer Gauge (red oil filled) to monitor main HEPA Filter pressure drop
Inflow 0.5 m/s (100 fpm)
Downflow 0.3 m/s (60 fpm)
MOC Outer Cabinet Cold Rolled Steel Powder Coated (Optional Stainless Steel SS-304)
MOC Inner Cabinet Walls - single piece jointless SS 304 sheet with rounded corners
Top - perforated SS 304 grill for filter protection
Work Table Stainless Steel 304 grade (Optional Stainless Steel SS-316)
Digital Controller Optional
Internal Work zone (WxDxH feet) Approx 2 x 2 x 2 3 x 2 x 2 4 x 2 x 2 5 x 2 x 2 6 x 2 x 2
External Size (WxDxH feet) Approx 2.4 x 2.7 x 6.9 3.4 x 2.7 x 6.9 4.4 x 2.7 x 6.9 5.4 x 2.7 x 6.9 6.4 x 2.7 x 6.9
No. of HEPA Filter 2 2 2 2 2


Smart Features

  • Brushless DC Blower / Motor: Energy efficient & reliable performance
  • HEPA Filtered Exhaust: Safe recirculation or canopy exhaust connection
  • Aerodynamic Airflow Grills: Maintains safety & prevents blockage
  • UV Germicidal Sterilization: 254 nm wavelength for effective sterilization
  • Ergonomic Design: Spacious work area with operator comfort
  • Digital Controller (Optional): Advanced monitoring & control

Optional Features

  • Analog Magnehelic Gauge (Dial Type) in lieu of manometer gauge
  • Digital Magnehelic Gauge with electronic filter choke alarm
  • Inclined manometer or magnehelic gauge to monitor pressure at exhaust HEPA filter
  • Interlocking of UV germicidal tube will auto switch off UV light when the door is opened
  • Microprocessor LCD controller with digital display for status indication of ON/OFF - Blower, ON/OFF - UV Lamp & ON/OFF - LED Lamp
  • Blower failure status indication
  • Door alarm when sash is opened above safe height of 8"
  • ULPA filter having 99.97% efficient at 0.1 to 0.3 micron particulates for ISO class 4 work cleanliness condition
  • Hour meter for totalizing UV light burning hours
  • UV light timer for automatic ON/OFF cycle of chamber sterilization

Applications

Pharmaceuticals

Sterile pharmaceutical formulation and handling.

Chemicals

Safe chemical and biological sample handling.

Institutes

Academic and microbiology research laboratories.

R&D Labs

Advanced research and infectious agent handling.

Quality Control