Automatic Abel Flash Point Tester
Accurate Results for Safer Operations. For Petroleum Products, Solvents & Flammable Liquids. Test Today for a Safer Tomorrow.
Flash Point is the lowest temperature at which application of the ignition source causes the vapour of a specimen of the sample to ignite under the specified condition of the test. The temperature of the approximately 70 ml test specimen is increased rapidly at first and then at a slower constant rate as the flash point is approached. At specified intervals a test flame is passed across the cup, to measure the tendency of the test specimen to form a flammable mixture with air under controlled laboratory conditions.
Our goal is to deliver precision laboratory instruments and petroleum testing solutions that are reliable, automated, accurate, and built to provide long-term performance.
Standards
Conforms to international testing specifications and quality standards.
- ISO 13736 / IP 170, ISO 1516, ISO 1523
Features
Engineered with single action setting, automated operation, and touch screen control.
- Single Action Setting: The Flash Detection sensor and temperature sensor are permanently mounted on a lid, which allows easy setting of the specimen.
- Easy Operation: Select a Test Mode and enter the expected flash point. While instrument executes the test, you are free to do other lab work. The tester follows the exact procedures prescribed in the test method and the completion of the test cycle is signalled by buzzer. The test result is brightly shown in VFD and same will be stored in the HMI.
- High Accuracy & Safe Operation
- Automated Test Cycle with Touch Screen Control
- Built-in Data Storage
Key Specifications
| Range | -10 to +100 °C |
|---|---|
| Test Method | ISO 13736 / IP 170, ISO 1516, ISO 1523 |
| Ignition Source | Electrical ignitor with LPG gas |
| Temperature Sensor | PT-100 in stainless steel |
| Flash Detector | CRC |
| Controller | Touch Screen, Colour Display with PLC with audio visual alarm, 3-wire RTD temperature sensor check, free potential flame detector as i/p. with automatic barometric reading correction. |
| Heating | Metal block with external |
| Inbuilt Memory | Storage memory for Flash |
| Flame-Sampling Arrangement | 10 Rpm, C. 12 v or 24V D.C., gear motor, vertical movement reciprocating to & fro motion. |
| Heater | 800 W |
| Ignition Transformer | Continuous o/p of 6 Kv. D.C. from 230 v A.C. i/p. |
| Overall Size (LxWxH) | 280 mm (W) X 530 mm (D) X 415 mm (H) |
| Gross Weight | 22 Kg |
| Power Supply | 230 V Ac, 50 Hz with 15 Amp. |
Automatically Shut the Machine and Horn the Buzzer in the Case:
- EFP + 30°C or at 100°C is reached
- Temperature sensor is found defective
- Flash detector is found defective
- LPG solenoid is working
- Stirrer not working
- Heater has gone
- Side Ignition coil/solenoid has gone
Installation Site
- Temperature: 0 to 45 degree C
- Humidity: Less Than 90% (No condensation)
Utility
- Power Supply: 230 V Ac, 16 Amp.
- GAS Supply: LP Gas or Natural Gas
- Pressure Less than 8 Kpa (in case of gas fired)
Accessories Will Be Supplied With Equipment
- Abel Cup & Lid – 1 No
- Thermal Printer – 1 No
- Thermal Printer Roll – 1 No
- Pc Interface Cable – 1 No
- Software For Above – 1 No
- Thermal Fuse – 1 No
- Signal Cable – 1 No
Applications
Petroleum Products
Flash point testing for petroleum fuels and oils.
Solvents
Testing industrial solvents and volatile liquids.
Flammable Liquids
Safety compliance and flash point analysis.
Chemical Industry
Process safety and quality control testing.
Paints & Coatings
Evaluating flash points for paints, varnishes, and resins.
Research & Quality Control
Advanced laboratory safety testing environments.
