Automatic Flash Point Apparatus (ASTM D 92)
Precision | Performance | Partnership. Automatic Flash Point Apparatus is a precision instrument used to determine the flash point of petroleum products and other flammable materials with accuracy, safety & reliability.
Flash Point is the lowest temperature at which application of the ignition source causes the vapour of a specimen of the sample to ignite under the specified condition of the test. The temperature of approximately 70 ml test specimen is increased rapidly at first and then at a slower constant rate as the flash point is approached. At specified intervals a test flame is passed across the cup, to measure the tendency of the test specimen to form a flammable mixture with air under controlled laboratory conditions.
Our goal is to deliver precision laboratory instruments and petroleum testing solutions that are reliable, automated, accurate, and built to provide long-term performance.
Standards Compliant
Conforms to international testing specifications and quality standards.
- ISO 2592 | ASTM D 92 | IP 36 | IS 1448 (P-69)
Features & Benefits
Engineered with single action setting, automated operation, touch screen control, and auto fire point detection.
- Single Action Setting: Simplifies operation
- Easy Operation: User friendly interface
- Temperature Range: - 70 to 400°C ±0.5°C
- Test Method: ISO 2592, ASTM D 92, IP 36, IS 1448 (P-69)
- Ignition Source: Gas flame with two pilot electric coil
- Temperature Sensor: PT-100 in stainless steel sheath
- Flash/Fire Detector: Ionization principle based flash detector sensor
- Controller: Microprocessor based process controller with LED display & visual alarm for status indication
- RTD Temperature Sensor: Free potential flame detector sensor as life with automatic barometric reading correction
- Touch Interface: For data storing
- Flame Sampling Arrangement: 10 RPM, D.C. 12 V or 24V DC gear motor, vertical movement reciprocating up & down
- Heater: 800 W, 230 V
- Electrical Ignition: For pilot flame sampling, ignition transformer having continuous O/P of 10.6 KV, D.C. from 230 V.A.C. I/P
- Dimensions (LxWxH): 280 mm (W) x 530 mm (D) x 415 mm (H)
- Gross Weight: 22 Kg
- Power Supply: 230 V AC, 50 Hz with 15 amp capacity
Auto Fire Point Detection
In addition to the automatic detection of flash point, fire point can be determined automatically too. The fire point is detected when the ionisation ring detects 5 sec for continuous burning.
Automatically Shut the Machine & Horn the Buzzer in the Case:
- FPT >300°C or at 400°C is reached
- Temperature sensor is found defective
- Flash detector is found defective
- 1st not set in place
- 5 not set in place
- Water has gone
- Side ignition coil/solenoid has gone
Dimension & Weight
- Dimension (LxWxH): 1686 x 321.586 x 414.536 (±15.55437)
- Net Weight: 64 lbs (29kg)
Shipping Information
- Shipping Weight: 78 lbs (35kg)
- Dimensions: 8.2 cu. ft.
Accessories Will Be Supplied With Equipment
- Cooking Bulb 5 No
- Needle 1 No
- Syringe 1 No
- Cooking Bulb Filling Rack Set 1 No
- SS Tray 1 No
- Ceramic Board Plate 4" 1 No
Spares Required For 5 Year Trouble Free Operation
- Cooking Bulb 20 Nos
- Temperature Controller 1 No
- Solid State Relay 3 No
- Switchgear (Mainswitch & Bulb) 3 set 3 No Each
- Ceramic Spill Bowl (catch) 6" 2 No
- Ceramic Board Plate 4" 1 No
- Syringe Filter Needle & Syringe 1 No
Applications
Pharmaceuticals
Testing chemical solvents and flammable substances.
Chemicals
Flash and fire point safety testing.
Institutes
Academic and petroleum research laboratories.
R&D Labs & Quality Control
Industrial quality assurance and safety testing.